The nfpa and osha require flammable cabinets to be designed and constructed to specific requirements.
Flammable storage cabinet requirements osha.
29 cfr 1926 152 b indoor storage of flammable and combustible liquids.
This citation echoes the formerly mentioned requirements for fire exit routes not to be unobstructed.
After examining the proper flammable storage containers sizes you must further consider the flammable liquid storage requirements and the total amount of liquids you are permitted to store in a single area.
Flammable or combustible liquids shall not be stored in areas used for exits stairways or normally used for the safe passage of people.
For example no safety cabinet is required to store less than 25 gallons of category 1 flammable liquids in approved containers.
No more than 25 gallons of flammable liquids shall be stored in a room outside of an approved storage cabinet.
Next let s look specifically at osha s flammable liquids regulations.
When is a flammable liquid storage cabinet required.
Per 1910 106 d 3 ii storage cabinets must be designed and constructed to limit the internal temperature to not more than 325 f when subjected to a 10 minute fire test and the cabinets must be labeled in conspicuous lettering flammable.
Osha flammable liquid storage regulations.
Designed to meet osha and nfpa standards sure grip ex cabinets are constructed of sturdy 18 gauge 1 mm thick double wall welded steel with 1 1 2 inch 38 mm of insulating air space.
Protect workers reduce fire risks and improve productivity by storing flammable fuels and chemicals in code compliant flammable storage safety cabinets.
The osha standard sets volume limits on flammable chemicals based on its flammable classifications.
Models with powder coated yellow finishes and safety signage in large red letters are easily identified for storage of flammable liquids.
Osha flammable liquid storage regulations click here to visit www osha gov 29 cfr 1926 152 a 2.
Flammable storage cabinets cannot limit the use of exits stairways or other areas normally used for the safe egress of people 29 cfr 1910 106 d 5 i.
1910 106 d 3 ii a states that flammable materials cabinets shall be constructed in the following manner.
For category 3 flammable liquids with a flashpoint at or above 100 f.
Osha flammable storage limits in a single area.
For storage of liquefied petroleum gas see 1926 153.
The nfpa osha and ufc require flammable cabinets to be designed and constructed to specific requirements.
Storage cabinets another fundamental means of fire protection is the use of flammable storage cabinets.